Skip to main content

Aluminium Window Cost Calculator

Estimates the cost of aluminium windows by size, glazing and installation, as a budget check before you ask installers for quotes.

A typical brick veneer house in Sydney with eight windows averaging 1.2 m wide and 1.4 m high has about 13.4 m² of window area to price. Multiply that area by the rate for your glazing and frame, add the installation charge for each window, and you have a budget figure before any quote arrives.

Aluminium is a common frame material for windows in Australia, and its price depends on three choices that matter as much as size: the frame, the glazing and the finish. A thermally broken frame has an insulating barrier between the inside and outside faces of the aluminium. It slows heat transfer and reduces condensation on the inside face in cold weather. A standard frame costs less but conducts heat readily, which is a problem in cool southern areas such as Hobart or the Snowy Mountains, where condensation around the frame is a recurring concern.

Glazing sets the second part of the price. Single glazing costs least but has the poorest thermal performance, and it suits only unheated spaces. Double glazing, with two panes separated by a sealed air or argon gap, is the usual baseline for new homes and renovations. Low-emissivity (low-e) double glazing adds a coating that reduces radiant heat transfer, and its benefit depends on the climate and on how the home is heated and cooled. Glazing is also one of the inputs to the NatHERS energy assessment used to show compliance with the energy efficiency provisions of the National Construction Code (NCC).

Installation is usually charged per window, not per square metre. Large openings, difficult access, second-storey work and removal of older frames set into masonry can raise the labour cost well above the standard rate. The calculator lets you include or leave out the installation charge, so you can compare supply-only and supplied-and-installed prices.

Treat the result as an early estimate, not a quote. Before you order, ask at least two or three fabricators or installers for written quotes that name the product series, the glass make-up and the performance ratings, and confirm which items are included.

The result updates automatically.

Count aluminium windows and glazed doors

Bedroom: 1.0–1.4 m (about 3.3–4.6 ft) · Living room: 1.4–2.0 m (about 4.6–6.6 ft)

Bathroom: 0.6–0.9 m (about 2–3 ft) · Bedroom: 1.2–1.5 m (about 3.9–4.9 ft)

Uw ≈ 1.4–2.0 W/(m²·K) · The most common choice · Meets thermal requirements in most cases

The rate per square metre is a reference for the material and fabrication of the window, and it varies with glazing type, frame system and finish. Installation is charged per window. Adjust the rates to the quotes you receive from local fabricators and installers.

Covers removal of the old window, fitting, sealing and adjusting the sashes.

Installer's labour for each window replaced.

Estimated total cost

~$4,069

6 windows · 10.1 in total

Material (manufacturing)
$3,679
Installation
$390
Total (estimate)
$4,069
Area per window
1.68 m²
Total area
10.1 m²
Price used
$365/m²

Turn this calculation into a quote for your client

We're building a tool for professionals. Be among the first to try it.

Share

How it works

1

Enter the number of windows you are replacing or installing.

2

Enter the average width and height of the windows, in metres.

3

Choose the glazing type: single glazing, double glazing or low-e double glazing.

Formula

C = N × (L × H) × Pm + N × Pi
C — estimated total cost, in Australian dollars
N — number of windows
L — average width of each window, in metres (m)
H — average height of each window, in metres (m)
Pm — average rate per square metre of window, in Australian dollars per m², which varies with glazing type and frame
Pi — installation cost per window, in Australian dollars per window, when included

How the calculation works

Aluminium window cost: what drives the price

A window is one of the elements that most affects the thermal and acoustic comfort of a home, and one of the easiest to underestimate in a renovation budget. Replacing every window in a house adds up quickly, because the cost is spread across many openings and each one carries its own fabrication and installation charge. Knowing what makes up the price before you ask for quotes helps you compare like with like.

The frame: with or without a thermal break

The frame is the aluminium section that holds the glass and fixes the window to the wall. Two versions are common. A standard frame is a single extruded aluminium section. It is the cheaper option, but aluminium conducts heat readily, so the inside face of the frame can cool below dew point in cold weather and show condensation. In cool areas such as Hobart, Ballarat or the Snowy Mountains, that condensation can lead to moisture at the jambs and, over time, mould in the corners of a room.

A thermally broken frame has a polyamide barrier between the inside and outside aluminium profiles, which interrupts heat conduction through the frame. It costs more than a standard frame, and the premium varies between systems, so ask for quotes by product series rather than by a general description. As a working assumption rather than a regulatory rule, a thermally broken frame is the better specification for most renovations, because it helps the window perform closer to the performance the energy assessment assumes. Whether a particular frame is required depends on the NCC climate zone and the compliance pathway used for the house, so confirm this with the building surveyor or energy assessor.

Glazing: single, double and low-e

Single glazing uses one pane, typically 4 mm or 6 mm thick. It has the poorest thermal performance of the three options and suits only unheated spaces such as a shed or a verandah enclosure used in summer. For any habitable room where comfort matters, it is rarely the right choice.

Double glazing uses two panes separated by a sealed cavity filled with air or argon. The cavity reduces heat transfer compared with a single pane and is the usual baseline for new homes and most renovations. The spacer width and the gas fill both affect performance, so the exact make-up, for example 4 mm glass, 16 mm argon gap and 4 mm glass, should be written into every quote.

Low-emissivity (low-e) double glazing adds a thin metal coating to one of the glass surfaces. The coating reduces radiant heat transfer, keeping heat indoors in winter or limiting its entry in summer, depending on the design of the coating and the orientation of the window. In a climate with significant heating and cooling loads, such as Melbourne or Canberra, the difference is most noticeable on the glass that receives the most sun.

Market tiers rather than product names

The Australian market supplies aluminium windows through many fabricators, installers and manufacturers. Comparing by tier is more useful than comparing by name, because product lines change over time. The table below gives a general guide.

Window typeTypical market tier
Aluminium, single glazing, standard frameEntry level
Aluminium, double glazing, standard frameEntry to mid range
Aluminium, double glazing, thermally broken frameMid range
Aluminium, low-e double glazing, thermally broken frameMid to premium

Installation is usually charged per window. Large windows, difficult access, second-storey work and the removal of older frames set into masonry can raise the cost well above the standard rate.

Compliance: NCC, NatHERS, bushfire and wind

The National Construction Code (NCC), maintained by the Australian Building Codes Board, sets the minimum requirements for building work, and the states and territories apply it with their own variations. For houses, the energy efficiency provisions are commonly demonstrated through a NatHERS assessment, in which glazing performance is one of the inputs. Windows and external glazed doors are assessed against AS 2047, and the Window Energy Rating Scheme (WERS) provides a thermal rating that helps compare products. Glass selection and installation fall under AS 1288, which also sets requirements for safety glazing near floors and in wet areas. In bushfire-prone areas, AS 3959 links construction requirements, including glazing, to a Bushfire Attack Level (BAL). In cyclone-prone regions, such as parts of coastal Queensland, wind loads on housing are assessed under AS 4055 alongside the NCC.

Common mistakes

Measuring the old window instead of the opening. Give the fabricator the size of the masonry opening, wall to wall, rather than the size of the old frame. Old frames are often out of square, and the new frame needs a small clearance on each side for packers and sealant. The installer should set the clearance for your opening and state it in the quote.

Comparing quotes without the same specification. Two quotes at the same rate per square metre can describe different systems. Ask for the product series, the glass make-up, the performance classifications under AS 2047 and the thermal rating, if one is provided.

Assuming accessories are included. Locks, hinges, sealant, head flashing and the external sill are included in many quotes but not all. Check the full list before you sign.

Worked example

A brick veneer house in Sydney has eight windows, each averaging 1.2 m wide and 1.4 m high. Each window has an area of 1.2 × 1.4 = 1.68 m², so the total window area is 8 × 1.68 = 13.44 m². The calculator multiplies that total by the rate per square metre for the chosen glazing and frame, then adds the installation charge for each of the eight windows. The result is shown as a total in Australian dollars.

Edge cases

If the number of windows is zero, the total is zero. If the width or the height is zero, the window area is zero, so only the installation charge remains. If installation is excluded, that charge drops out and the total covers fabrication and supply only. A rate of zero per square metre leaves only the installation charge. Dimensions should always be entered as positive values in metres.

When to use this calculator

Use it to set a renovation budget, compare glazing options, or see how the number and size of windows affect the total. Do not use it as a quote. It does not include site access, scaffolding, making good the plaster and paint, removal of old frames, or bushfire and wind upgrades, and it does not replace an assessment by a building surveyor or energy assessor.

The calculator uses one average width and height for all windows in a run. If the windows in a house differ widely in size, group the windows of similar size, run the calculator for each group, and add the totals. A single average across very large and very small openings will misstate the total.

Frequently asked questions

What determines the cost of aluminium windows in Australia?

The price depends on three main factors: the glazing (single, double or low-e double), the frame (standard or thermally broken) and the size of each window. Double glazing with a thermally broken frame is a common mid-range choice, and low-e double glazing with a thermally broken frame sits at the upper end. Installation is usually charged separately, per window, and is higher for large openings, difficult access or removal of older frames. Enter the number of windows, their average size and the glazing type in the calculator to get a total estimate, then compare it with written quotes.

Is a thermally broken aluminium frame worth the extra cost in Australia?

In many cases it is. A standard aluminium frame conducts heat readily, which can cause condensation on the inside face in cold weather. A thermally broken frame has a polyamide barrier that interrupts this heat path, which reduces condensation and helps the window perform closer to its rated value. The price premium depends on the system and the supplier, so compare quotes by product series. Whether a thermal break is required depends on the NCC climate zone and the energy assessment for the house, so confirm this with the building surveyor or energy assessor before you decide.

What is the difference between standard double glazing and low-e double glazing?

Both use two panes separated by a sealed cavity, which reduces heat transfer compared with single glass. Low-e double glazing adds a thin coating that reflects radiant heat, reducing heat transfer further. The gain depends on the climate, the orientation of the window and how the home is heated and cooled, and it is usually most noticeable in heating and cooling costs over time. Low-e glazing costs more than standard double glazing. Ask the supplier for the thermal performance rating of each option so you can compare them directly, and check the glass make-up on each quote.

What should I ask a window supplier before comparing quotes?

Ask for the product series and the frame system, the exact glass make-up (for example, 4 mm glass, 16 mm argon gap and 4 mm low-e glass), the performance classifications for air infiltration, water penetration and wind pressure under AS 2047, and the thermal rating if one is available. Confirm whether locks, hinges, sealant, flashing, the external sill and installation are included, and whether the quote covers removal of the old frames and making good. Quotes that lack these details are hard to compare, because a lower price may reflect thinner sections or lower-performance glass.

When do energy efficiency rules apply to replacing windows in Australia?

Window replacement can fall under the National Construction Code, depending on the scope of the work. For houses, the energy efficiency provisions are commonly demonstrated through a NatHERS energy assessment, in which window performance is a key input. The exact requirements depend on the state or territory, the type of work and the climate zone, and the local building surveyor decides how the rules apply to your project. Confirm this before you order windows, because the choice of glazing and frame may need to match the assessment.

Does this calculator cover bushfire and wind requirements?

No. The calculator estimates the cost of the windows by size, glazing and installation, and does not check compliance. In bushfire-prone areas, the Bushfire Attack Level (BAL) set under AS 3959 can require specific glazing and frame systems, which may increase the cost. In cyclone-prone regions, wind loads on housing are assessed under AS 4055 and the NCC, and the window system must be specified to suit. Give the building surveyor or a licensed installer your site's bushfire and wind details before you request quotes, so the quotes reflect the required specification.

Related calculators

View all Climate & Energy calculators →

By RivoCalc · Reviewed under our editorial methodology · Updated 3 June 2026

This calculator gives an estimate only. Actual costs vary with the product, glass specification, frame type, site access, local building requirements and installer rates. Compliance with the National Construction Code, and with bushfire and wind requirements, is confirmed by the building surveyor, and a written quote from a licensed installer is needed before you commit.