Aluminium Window Cost Calculator
Estimate the cost of aluminium windows from the number and size of openings, the glazing type and whether fitting is included.
The cost of aluminium windows is the total window area multiplied by the price per square metre, plus a fitting charge for each window. For a semi-detached house in Cork with ten windows measuring 1.2 m wide and 1.4 m high, the total window area is 16.8 m², and that figure is the starting point before any installation charge is added.
Windows have a large effect on how warm, quiet and dry a home feels, yet they are often underestimated in renovation budgets. Replacing every window in a house can account for a significant share of the external works, so it pays to fix the area and the specification early, before quotes arrive and choices are made under time pressure.
Two decisions drive most of the price: the glazing and the frame profile. Single glazing has a high U-value and is rarely suitable for a heated room. Standard double glazing, usually a 4/16 argon/4 mm build-up, is the common minimum in new builds and replacement work. Low-emissivity (low-E) double glazing adds a coating that reduces heat loss through the glass and sits at the premium end of the market. On the frame side, a thermal break is a polyamide barrier that stops heat passing straight through the aluminium, and it is the better specification for most homes.
This calculator estimates the total for a set of windows with similar characteristics. It uses the number of windows, their average width and height, the glazing type and whether fitting is included. Enter your own figures to get a working estimate, then use it to check written quotes from local window fabricators and installers.
In Ireland, the thermal performance of windows is set out in Part L of the Building Regulations (S.I. 538/2017) and its Technical Guidance Document, and the Building Energy Rating (BER) process reflects how windows affect a home's energy rating. Windows also need CE marking under the Construction Products Regulation (EU) No 305/2011, with performance based on EN 14351-1. Ask for these classifications in any quote, because they are what separates windows that look similar.
The result updates automatically.
Count aluminium windows and glazed doors
Bedroom: 1.0–1.4 m (about 3.3–4.6 ft) · Living room: 1.4–2.0 m (about 4.6–6.6 ft)
Bathroom: 0.6–0.9 m (about 2–3 ft) · Bedroom: 1.2–1.5 m (about 3.9–4.9 ft)
Uw ≈ 1.4–2.0 W/(m²·K) · The most common choice · Meets thermal requirements in most cases
The price per m² is a reference for the Irish market, covering material and fabrication. It varies with glazing type, frame profile and finish, and installation is usually charged per window. Adjust the reference to the quote you receive from a local fabricator or installer.
Covers removal of the old window, fitting, sealing and adjusting the sashes.
Installer's labour for each window replaced.
Estimated total cost
6 windows · 10.1 in total
- Material (manufacturing)
- €3,679
- Installation
- €390
- Total (estimate)
- €4,069
- Area per window
- 1.68 m²
- Total area
- 10.1 m²
- Price used
- €365/m²
How it works
Formula
How the calculation works
Aluminium window costs: what determines the price
Windows affect comfort and energy use more than most elements of a renovation, yet they are often underestimated in budgets. The calculator estimates the total cost of a set of windows that share the same characteristics, based on the number of units, their average size, the glazing type and whether fitting is included. Understanding what sits behind each input helps you read quotes correctly before you commit.
The frame profile: with or without a thermal break
The profile is the aluminium frame that holds the glass and fixes the window to the wall. Two versions are common: without a thermal break and with a thermal break.
A profile without a thermal break is a single extruded aluminium section. It costs less than the equivalent thermally broken version, but aluminium conducts heat readily. In cold weather the inside face of the frame can fall below dew point, producing visible condensation. Over time this can lead to damp reveals and mould in room corners, particularly in cold, exposed or damp locations.
A thermally broken profile has a polyamide barrier that interrupts heat flow between the outside and the inside of the frame. The price difference is real, but in most renovation and new-build work it is the better specification. Part L of the Building Regulations and its Technical Guidance Document set performance requirements for windows, so the designer should confirm what applies to the specific project before the frame type is fixed.
Glazing: single, double or low-E
Single glazing has one pane of glass, typically 4 or 6 mm thick. Its U-value is high, which means it loses a lot of heat. It may still suit an unheated store or an unheated sunroom, but it is rarely appropriate for a habitable room.
Standard double glazing has two panes separated by an air or argon-filled cavity. Its U-value is considerably lower than that of single glazing, and it is the common minimum for new builds and replacement windows. A typical build-up is 4/16 argon/4 mm, meaning 4 mm glass, a 16 mm argon-filled cavity and 4 mm glass. The width of the spacer and the gas used both affect the result.
Low-emissivity double glazing (low-E) adds a thin coating to one of the glass surfaces. The coating reflects radiant heat back into the room in winter and limits solar heat gain in summer, depending on the coating type and the orientation of the window. It has the lowest U-value of the three options and is the premium choice. Its benefit is most noticeable in rooms that are heated for long periods, or in exposed locations where heat losses are larger.
Typical market tiers
The Irish market for aluminium windows is served by local fabricators and installers who buy profile systems from manufacturers and assemble the units in their workshops. Quotes often rely on a small number of profile systems, so the profile name and series matter more than the name of the fabricator. Use the table as a guide to how the three variables combine:
| Window type | Typical market tier |
|---|---|
| Aluminium, single glazing, no thermal break | Basic |
| Aluminium, standard double glazing, no thermal break | Basic to mid-range |
| Aluminium, standard double glazing, thermal break | Mid-range |
| Aluminium, low-E double glazing, thermal break | Mid-range to premium |
Installation is usually charged per window. Large units, difficult access, or the removal of old frames set in stone or brick can increase fitting costs considerably. Include the installation option only when fitting is part of the quote you are comparing.
Common mistakes when ordering aluminium windows
Measuring the old window instead of the opening. The figure to give a fabricator is the size of the masonry opening, from reveal to reveal, with a small clearance on each side for expanding foam and fixings. Using the size of the old frame as the reference is risky, because old windows may have irregular clearances or poorly executed seats.
Comparing quotes without the full specification. Two quotes at the same price per square metre may describe profiles from very different series. Ask for the profile name and series, the exact glazing build-up (for example 4/16 argon/4 low-E), the air permeability class under EN 12207, the watertightness class under EN 12208, and the wind resistance class under EN 14351-1. Without these details, the cheapest quote may mean thinner sections or lower-performance glass.
Forgetting what is included. Locking hardware, hinges, external sill, perimeter sealant and gaskets are included in many established fabricators' quotes, but not in all of them. Confirm the complete list before accepting any proposal.
What the result means, and when not to use it
The result is a planning estimate, not a formal quotation. Real costs depend on the fabricator, site access, the exact specification and local conditions. Use the calculator to plan a renovation budget or to check whether a quote falls in a plausible range.
The calculator is designed for standard casement or sliding aluminium windows of similar size. It is not designed for curtain walling, rooflights, shopfronts, bespoke glazing or heavy commercial systems. Those need a site survey and an itemised quotation.
A few edge cases are worth knowing. If the number of windows is zero, the total is zero. If the average width or height is zero, the area term is zero, and only the installation charge, if included, remains. Negative dimensions are not physically meaningful, so they should be corrected before the result is used.
When to consult a fabricator and a qualified professional
Before ordering, obtain two or three written quotes from fabricators with verifiable references on similar projects. Where the works are a material alteration to the building, the designer or building control officer should confirm that the windows meet the Part L requirements for the project. The European standards, adopted in Ireland as I.S. EN standards, set the test methods behind the performance classes, and the Construction Products Regulation (EU) No 305/2011 requires windows placed on the market to carry CE marking and be supported by a declaration of performance. Ask whether the declaration and the test reports are available for the specific system being quoted.
Frequently asked questions
What determines the cost of aluminium windows in Ireland?
The main factors are the glazing type (single, standard double or low-E double), the frame profile (with or without a thermal break), the total window area and whether fitting is included. Thermally broken, low-E double-glazed windows sit at the premium end of the market, while single glazing is the basic tier. Fitting is usually charged per window, and difficult access or the removal of an old frame set in masonry increases that charge. Enter the number and size of the windows in the calculator to see a total estimate, then compare it with written quotes.
Is a thermal break worth paying more for?
In most cases, yes. A thermally broken profile costs more than one without, but it reduces condensation on the inside of the frame and cuts heat loss through the aluminium. That matters most in cold, exposed or damp locations, where condensation and mould are more likely to develop. Part L of the Building Regulations and its Technical Guidance Document set performance requirements for windows in material alterations, so a designer may require it for some projects. Ask the fabricator for the thermal performance of the complete window, not only of the profile.
What is the difference between standard double glazing and low-E double glazing?
Both are double-glazed units with an air or argon-filled cavity, but low-E glass has a thin coating that reduces heat loss through the glass, so it has a lower U-value (the rate at which heat passes through the glazing). The exact U-value depends on the spacer, the gas and the coating, so use the figure declared for the product under the relevant European standard (EN 673 for the glass, EN ISO 10077-1 for the whole window) rather than a general range. The price difference shows up in the quote, and the benefit depends on the room, its orientation and how often it is heated. The glazing build-up and the declared U-value should be stated in any written quote.
Which details should I ask for when comparing window quotes?
Ask for the profile name and series, the glazing build-up, and the classes for air permeability (EN 12207) and watertightness (EN 12208). Also ask for the wind resistance classification under EN 14351-1, and whether the quote includes hardware, external sill, perimeter sealant and gaskets. Quotes that leave out these details are not directly comparable, because a lower price can mean thinner sections or lower-performance glass. Ask for the CE marking and the declaration of performance for the system being installed.
When does Part L apply to replacement windows?
Whether Part L applies depends on whether the work counts as a material alteration of the building, and on the scope of the project. The Technical Guidance Document sets out the requirements for each case. The designer or building control officer confirms what performance the windows need for a given project, so it is worth asking before the specification is fixed. Even where Part L does not apply, thermally broken, double-glazed windows remain a sensible choice for comfort and for controlling condensation.
Do aluminium windows need CE marking in Ireland?
Yes. Windows and external doors placed on the EU market must carry CE marking under the Construction Products Regulation (EU) No 305/2011, and the manufacturer must issue a declaration of performance. For windows, the relevant harmonised standard is EN 14351-1, which covers performance such as air permeability, watertightness and wind resistance. The CE marking confirms that the product conforms to the declared performance, not that a particular installation is correct. The installer should provide the declaration for the system fitted to your home.
Related calculators
View all Climate & Energy calculators →
By RivoCalc · Reviewed under our editorial methodology · Updated 3 June 2026
This calculator gives an estimate for planning purposes only. Real costs depend on the fabricator, site access, the exact specification and local conditions, and the energy performance of a window depends on how it is installed and on the building it is fitted to. Obtain written quotes and confirm compliance with the Building Regulations with a qualified professional before ordering.
