A 4 m × 2.5 m wall built from 30 × 20 cm hollow clay bricks, with a 1 cm mortar joint and a 10% waste allowance, needs 169 bricks. That is about 15.4 bricks per square metre before waste. If the mortar joint is left out of the calculation, the same wall appears to need 184 bricks, which is 15 more than it actually takes.

The number of bricks per square metre depends only on the visible face of the brick and the thickness of the joint. With a 1 cm joint, each 30 × 20 cm brick occupies 31 × 21 cm, or 651 cm² (0.0651 m²), against a bare face of 600 cm². Leaving the joint out therefore overstates the count by about 9%, which means ordering bricks you will not use. The wall thickness does not change the count: bricks with the same face in 7, 11, 15 or 22 cm depths give the same number per square metre, but the finished wall is wider. Enter the wall length and height, the brick face dimensions, the joint thickness and the waste allowance. The calculator works out the exact total and rounds up to the next whole brick.

The calculator suits simple masonry walls: an internal partition, a garden wall, or the infill of an existing opening, in hollow or solid clay units. It is designed for non-structural walls. A wall that carries loads, retains soil, or forms part of a building's structure needs a design prepared by a chartered engineer, and the number of units is then only one part of the job. Enter the net dimensions, with door and window openings deducted from the wall area, because the calculator treats the wall as solid.

The waste allowance covers cut bricks, broken units, and the awkward pieces at corners, at door and window reveals, and where walls meet columns or where chases are cut for cables and pipes. The 5% option suits a simple rectangular wall with few openings. The 10% option suits walls with several openings or many services, or where bricks are cut on site. Set the allowance to match the shape of the wall rather than the size of the job.

The result updates automatically.

Typical ceiling height: 2.5–2.7 m (flat); up to 3.0 m (house) (about 8.2–8.9 ft; 9.8 ft).

Standard hollow brick: 30 cm · Acoustic brick: 37 cm (about 11.8 and 14.6 in)

Standard hollow brick: 20 cm · Thermal brick: 19 cm (about 7.9 and 7.5 in)

Typical on-site value: 1 cm (about 3/8 in)

Plain wall: 5% · With cut-outs and openings: 10%

Bricks needed

218bricks

for a wall of 13.5

Wall area
13.50 m²
Bricks per unit area
15.4 unid./m²
Effective area per brick
651 cm²

Turn this calculation into a quote for your client

We're building a tool for professionals. Be among the first to try it.

Share

How it works

1

Enter the length and height of the wall in metres. Deduct door and window openings first.

2

Enter the length and height of the brick face from the product data sheet. The example uses 30 × 20 cm.

3

Set the mortar joint thickness, usually 1 cm (0.01 m), unless the designer specifies otherwise.

Formula

N = ⌈(A × (1 + D/100)) / ((L + J) × (H + J))⌉
N — Number of bricks needed, rounded up to the next whole brick
A — Wall area (m²) = length × height
D — Waste allowance (%)
L — Length of the brick face (m)
H — Height of the brick face (m)
J — Mortar joint thickness (m), usually 0.01 m

How the calculation works

How many bricks does a wall need?

Internal partitions and garden walls are built from many types of masonry unit, and the question of how many to order comes up on almost every job. The calculation is simple in principle: divide the area of the wall by the effective area of one brick, including the mortar joint, and round up. The trap is the joint itself. One centimetre of mortar per brick looks small, but it changes the count by about 9% on a 30 × 20 cm face, and that error only shows up when the order is placed.

The formula and what goes into it

The calculator uses N = ⌈(A × (1 + D/100)) / ((L + J) × (H + J))⌉. The wall area A is the length multiplied by the height. The waste allowance D is added to that area as a percentage. The effective size of one brick is its face length and face height, each increased by the joint thickness J, because every brick occupies a cell that includes one joint along its length and one bed joint above its height. Dividing the adjusted wall area by this cell size gives the number of bricks, and the ceiling function rounds the result up to the next whole brick.

Take a 5 m × 2.7 m interior partition as an example. The area is 13.5 m². A 30 × 20 cm brick face with a 1 cm joint occupies 31 × 21 cm, which is 651 cm² or 0.0651 m². Without any waste, 13.5 ÷ 0.0651 gives 207.4, which rounds up to 208 bricks. With the 5% allowance, the adjusted area is 14.175 m², and 14.175 ÷ 0.0651 gives 217.7, so the order is 218 bricks. The waste allowance is applied to the area before the division, so it scales the result in proportion to the wall size.

The formula assumes that every brick occupies the same cell. It does not model bonding patterns, half bricks at the ends of courses or openings in the wall. Those effects are covered by the waste allowance, which is why the choice of percentage should follow the shape of the wall.

Why the mortar joint matters

The joint is the layer of mortar between units. Horizontal bed joints carry the load from one course to the next, and vertical perpend joints separate the units along each course. The calculator uses one thickness for both, which is what the formula expresses through the single symbol J. European standard EN 771-1 sets the requirements for clay masonry units, but it does not fix the joint thickness, which is set by the design and by the way the wall is built. The value of 10 mm used as the default here is a common reference point, and the designer or the unit manufacturer's instructions should confirm the thickness for the actual job.

Joint thickness has two practical effects. Thicker joints use more mortar and make the dimensions of the finished wall less precise, and they can reduce the strength of the masonry. Very thin joints need tighter tolerances in the units themselves and more careful laying. The calculator shows the effect on the brick count, but it does not estimate the mortar quantity, which needs a separate calculation based on the joint volume.

Brick face and wall thickness

The face of the unit sets the count, and the depth of the unit sets the width of the wall. Hollow clay bricks with a 30 × 20 cm face are made in several depths. A 7 cm unit is used for light partitions, and once plastered on both sides the finished wall is about 10 cm thick. An 11 cm unit is a common choice for an internal partition, with better sound insulation and room for pipes and cables. A 15 cm unit suits walls with greater structural or thermal demands, and a 22 cm unit is used for single-leaf external walls, where thermal performance is assessed under Part L of the Building Regulations.

Because the face is the same in every case, the number of bricks per square metre is identical for all four depths. The depth changes the width of the wall, its weight, the cost per unit and, in practice, the acoustic and thermal behaviour of the finished construction. Internal walls that must limit sound transmission are assessed under Part E of the Building Regulations, so the depth should be confirmed with the designer before the order is placed.

Hollow units are lighter and perform better on heat and sound, which suits new internal walls. Solid units are denser and have higher compressive strength, so they are used for garden walls and for repairs to older traditional masonry. The calculator works in the same way for both types, because it uses only the face size and the joint. The choice between them is a design decision, and the product data sheet should be checked for the unit's dimensions and compressive strength before ordering.

Ordering and buying in Ireland

Masonry units are available from large DIY retailers and from builders' providers. Large DIY retailers stock units in standard sizes and sell single units, which suits small quantities or a job that needs material at short notice. Builders' providers usually sell by the pallet, and a whole pallet often carries a lower unit price, so compare quotes for larger walls. Enter the price per brick in the calculator to estimate the material cost. The estimate is only as good as the price entered, and it excludes delivery, mortar and wall ties.

Ask the supplier for the face and depth dimensions on the product data sheet, and check that all units come from the same batch. Colour and size can vary between production runs, and a mixed delivery can leave visible differences in the finished wall. Ordering a little more from one batch is usually simpler than trying to match a later delivery.

Common mistakes to avoid

Leaving out the joint. A 1 cm joint changes the count by about 9% for a 30 × 20 cm face. Ignoring it means ordering more units than the wall needs, and the extra cost is avoidable.

Using the gross wall area. Door and window openings must be deducted from the wall area before the calculation. If they are not, the count is too high. The openings do create cut bricks, and the waste allowance should cover those cuts rather than the full opening area.

Using no waste allowance. Walls are rarely exact multiples of the brick size. Cuts at corners, at door and window reveals, at lintels and around services always create waste. Buying the exact count leaves no margin for breakage or for cutting errors.

Using the wrong dimensions. The calculator uses the face length and height seen from the wall, not the depth. Depth changes the width of the wall but not the number of units per square metre. Entering the depth in place of the height produces a result that looks plausible and is wrong.

Using one calculation for a double wall. Each leaf of a double wall is counted separately, with its own face size and its own waste allowance. The number of units per square metre is the same on both leaves if the face is the same, but the unit cost and the depth may differ, so each leaf should be priced on its own.

Ordering without a reserve. Keeping a few spare units from the same batch is cheaper than trying to match a later delivery for repairs, which is the most common reason for buying a small extra quantity at the end of a job.

Standards, regulation and professional advice

The standard for clay masonry units is EN 771-1, adopted in Ireland as I.S. EN 771-1 and published by the National Standards Authority of Ireland (NSAI). Structural design of masonry follows Eurocode 6 (EN 1996), applied with the Irish National Annex. Within the Building Regulations, Part A (Structure) and its Technical Guidance Document A cover structural design, Part E covers sound, and Part L covers the conservation of fuel and energy. Where building work requires planning permission or is covered by building control, the design must follow these requirements and be signed off by the relevant professional.

A chartered engineer should design any wall that carries load, retains soil, forms part of the building's structure, or needs a support over a large opening. A simple internal partition or a garden wall that carries no load can be quantified with this calculator, but the quantity is only one part of the work. Mortar, wall ties, damp-proofing and lintels need their own estimates.

When not to use this calculator

The calculator is for simple masonry walls with a regular face. It is not suitable for retaining walls, fire walls, parapets or arches. It does not account for a designed bond pattern, curved walls or irregular units, which need a count made from a sketch with an allowance added for the curved or shaped pieces. Mortar, wall ties and lintels need separate estimates, and any structural element needs a designed solution rather than a quantity estimate.

Summary

The number of bricks depends on three things: the wall area, the brick face including the joint, and the waste allowance. Use the calculator to size the order, keep spare units from the same batch, and have any load-bearing or retaining wall checked by a chartered engineer before work starts.

Frequently asked questions

How many bricks do I need per square metre of wall?

With 30 × 20 cm bricks and a 1 cm mortar joint, each brick covers 0.0651 m² of wall, which gives about 15.4 bricks per square metre before any waste. A 5% allowance brings this to about 16.1 bricks per square metre, and a 10% allowance to about 16.9. For planning, many people round up to 17 bricks per square metre with a 10% allowance. The exact figure depends on the brick face and the joint thickness, so enter your own dimensions in the calculator before placing the order.

Does the thickness of the brick change how many I need?

No. The number of units per square metre depends only on the face size and the joint thickness. A 7, 11, 15 or 22 cm depth with the same 30 × 20 cm face gives the same count. The depth changes the finished wall width, the weight, the cost per unit and the acoustic and thermal behaviour. For internal partitions that must limit sound transmission, check the requirements in Part E of the Building Regulations before choosing a depth. The designer should confirm the depth for any wall that carries load or must meet thermal requirements under Part L.

What waste allowance should I use for bricks?

The 5% option suits a simple rectangular wall with few openings. Use 10% for walls with several window and door openings, electrical boxes or pipe chases, or where bricks are cut on site. For renovation work with irregular openings, a higher allowance is the safer choice, because salvaged or mixed units are harder to match. Keep a few spare bricks from the same batch after the job is finished, for later repairs.

What is a mortar joint and what thickness should I use?

The mortar joint is the layer of mortar between bricks, both the horizontal bed joints and the vertical perpend joints. The calculator uses 1 cm (0.01 m) as the default, which is a common reference for clay units. The designer or the unit manufacturer should confirm the thickness for the actual wall. Thinner joints need more precise laying and tighter tolerances in the units. Thicker joints use more mortar, make the finished dimensions less precise and can reduce the strength of the masonry, so the design should specify the thickness.

What is the difference between hollow and solid clay bricks?

Hollow clay bricks have internal cavities that make them lighter and give better thermal and acoustic behaviour, which is why they suit new internal walls. Solid bricks are denser, heavier and have higher compressive strength, so they are used for garden walls and for repairs to older traditional masonry. The calculator works the same way for both, because it uses only the face size and the joint. Check the product data sheet for the unit's dimensions and compressive strength before ordering.

When should a chartered engineer check a brick wall?

Always when the wall is load-bearing, retains soil, forms part of the building's structure or needs a support over a large opening. Building work covered by building control must comply with the Building Regulations, and the design of structural masonry follows Eurocode 6 (EN 1996) with the Irish National Annex. For a simple internal partition or a garden wall that carries no load, the calculator is sufficient for the quantity of units. It does not replace the engineering design of any structural element.

Related calculators

View all Measurements & Quantities calculators →

By RivoCalc · Reviewed under our editorial methodology · Updated 4 June 2026

This calculator gives an estimate of the number of units for simple, non-structural masonry walls. It does not replace the structural design of a load-bearing or retaining wall, which must be prepared by a chartered engineer and comply with the Building Regulations. Actual quantities depend on the real unit dimensions, joint thickness, cutting and site wastage.