Air Conditioner Energy Use Calculator
Estimates the monthly electricity use of an air conditioner or heat pump in kWh, for cooling or heating, from unit size, efficiency and hours of use.
A 3.5 kW split system with a cooling EER of 3.5, run for 8 hours a day over 30 days, uses 240 kWh in a month. In heating mode with a COP of 4.0, the same unit uses 210 kWh for the same hours, which is 30 kWh less. The calculator reaches figures like these from four inputs: the rated capacity of the unit, its efficiency ratio, the hours of use per day and the days of use per month.
The two ratios measure the same relationship from different sides. EER (Energy Efficiency Ratio) applies to cooling and COP (Coefficient of Performance) applies to heating. An EER of 3.5 means each kilowatt-hour of electricity moves about 3.5 kWh of heat out of the room. A COP of 4.0 means each kilowatt-hour of electricity delivers about 4.0 kWh of heat into the room. Both values come from standardised test methods, and EN 14825 is the European standard for testing and rating these units. The figures on a data sheet describe rated conditions, which may not match every home.
Using the calculator takes a few short steps. Enter the rated capacity from the data sheet, choose cooling or heating, enter the matching efficiency ratio, then add your daily hours and monthly days. The result is the estimated electricity use for the month. To turn that into a running cost, multiply the kWh by the rate per kWh on your power bill. The rate field starts with a reference value, which you should replace with your own.
The calculator suits planning rather than metering. It helps compare units before you buy, check whether a replacement would lower your use, or explain a higher than expected bill. It is less suited to multi-zone systems or units that spend most of their time at part load, because one rated ratio cannot describe how efficiency changes across the load range. A cold winter in Christchurch or Queenstown, or a summer heatwave in Hamilton or Auckland, will move real use away from the estimate, so treat the result as a planning figure.
The result updates automatically.
Cooling/heating output from the energy label. E.g. 3.5 kW = 12,000 BTU.
Electricity rates vary by region, retailer and plan, so the rate on your own power bill is the reliable input. Electrical installations in New Zealand follow AS/NZS 3000, and the mains supply is 230 V at 50 Hz. Heat pump efficiency ratings are stated under the test conditions of EN 14825.
Average running time during the period you're looking at.
In July/August, count 30 days. In shoulder months (May, October), use fewer.
Estimated monthly usage
monthly cost: $38.50
- Actual electrical draw
- 0.97 kW
- Cost per hour
- $0.21
- Monthly cost
- $38.50
- Annual cost (at the same rate)
- $462.00
How it works
Formula
How the calculation works
How much electricity does an air conditioner use?
An air conditioner is often one of the largest electrical loads in a New Zealand home during summer, and a heat pump running through winter can make a noticeable difference to the power bill. Knowing the monthly kWh figure in advance helps you compare units before buying, check whether a bill is in line with your usage, and judge whether an older unit is worth replacing. This calculator estimates that figure from the unit's rated capacity, its efficiency, and how many hours and days it runs.
The formula: from rated capacity to kWh
The capacity printed on a data sheet, in kW, describes the heat the unit moves into or out of the room. It is not the electricity the unit draws. Electricity use is lower because a heat pump moves more heat energy than the electrical energy it consumes. The efficiency ratio links the two: EER for cooling and COP for heating.
Dividing the rated capacity by the efficiency ratio gives the electrical power drawn while the unit runs. Multiplying that by the hours per day gives kWh per day, and multiplying again by the days per month gives kWh per month. The formula used by the calculator is:
C = (P ÷ η) × H × D | Cost = C × p
Here C is monthly electricity use in kWh, P is the rated capacity in kW, η is the EER or COP, H is hours of use per day, D is days of use per month, and p is the price per kWh. The cost part only multiplies the monthly kWh by that rate.
Worked example: a 3.5 kW unit with an EER of 3.6, run for 6 hours a day over 30 days, draws 3.5 ÷ 3.6 ≈ 0.97 kW while running. Over 6 hours that is about 5.8 kWh per day, and over 30 days about 175 kWh per month. The EER of 3.6 is an illustrative value, not a figure for any specific product. Multiply the monthly kWh by the rate on your bill to obtain the running cost.
Enter the capacity in kilowatts, as the data sheet gives it. Mixing units is the most common source of large errors, as covered under common mistakes below.
EER for cooling, COP for heating
EER and COP are both ratios of useful heat transferred to electrical energy consumed. The difference is the direction. EER describes removing heat from a room, while COP describes adding heat to it. The European standard EN 14825 defines the test and rating methods for air conditioners and heat pumps, so the values can be compared across manufacturers on a consistent basis. The figures are tied to the stated test conditions, and efficiency changes with outdoor temperature, which is why real use can differ from the estimate.
On many split units the heating COP is listed higher than the cooling EER, so the same rated output can require less electricity in heating mode. For the same 3.5 kW output, an EER of 3.6 gives about 0.97 kW of electrical draw in cooling, and a COP of 4.0 gives about 0.875 kW in heating. The gap varies by model, and heating efficiency generally drops in very cold weather, so check the data sheet for the figures that apply to your unit.
How unit size and efficiency change the result
The table below uses 6 hours a day and 30 days a month, the same basis as the worked example. The EER values are illustrative and show the effect of each variable on its own.
| Unit size | Efficiency (EER) | kWh per month |
|---|---|---|
| 2.5 kW | 3.6 | 125 |
| 3.5 kW | 3.0 | 210 |
| 3.5 kW | 3.5 | 180 |
| 3.5 kW | 4.2 | 150 |
| 5.3 kW | 3.6 | 265 |
The same 3.5 kW unit uses 60 kWh less per month at an EER of 4.2 than at 3.0 in this example. The formula scales linearly with capacity, so a larger unit at the same efficiency uses more electricity for the same hours. In practice an oversized unit also cycles on and off, which the formula does not model.
Hours and days: the largest lever
Electricity use is directly proportional to hours and days. Doubling the hours per day doubles the estimate, and running time is usually the biggest single factor in a household's use. A unit run for 8 hours a day uses about a third more than one run for 6 hours, with everything else unchanged.
Turning kWh into a cost
Multiply the monthly kWh by the price per kWh on your bill. Three points matter here. First, the rate on a bill can vary by time of day, so if the unit mainly runs in one period, use the rate for that period. Second, check whether the rate includes GST. Third, the daily charge on a bill is separate from the energy charge, and this calculator does not include it. The reference rate in the calculator is only a starting point, so replace it with the price you actually pay.
Saving energy without losing comfort
Setting the temperature lower than needed increases electricity use, and the effect grows the further below a comfortable level you set. Many units have sleep or eco modes that reduce output, which can help overnight. Keep doors and windows closed while the unit runs, and use curtains or blinds on sunny sides to reduce the heat load. Clean the filters at the intervals given in the owner's manual, because blocked filters restrict airflow and make the unit work harder for the same comfort.
When replacing the unit makes sense
The calculator is a useful starting point for replacement decisions. Estimate the kWh for the existing unit using its original rating, estimate the kWh for a candidate replacement, and compare the difference over a year. Whether that saving justifies the installation cost depends on how many hours the unit runs and the price of electricity where you live. Older units with low ratings and heavy use are the strongest cases for replacement.
Edge cases
Zero hours or zero days gives zero kWh, which matches a unit that is not run. A higher EER or COP always lowers the estimate. An efficiency value of zero cannot be used, because the formula divides by it, so enter the figure from the data sheet. Negative values have no physical meaning for hours, days or capacity, so enter positive figures only.
When not to use this calculator
Multi-split systems with several indoor units and ducted systems with several zones are not modelled, because the rooms share one outdoor unit and their load changes through the day. Units that spend most of their time at partial output are only roughly described by a single rated ratio. Portable units are often less efficient than split systems, so use the figures from the unit's own label. If the data sheet gives no EER or COP, the calculator cannot give a reliable figure, and a better guide is the metered use from a full month.
Common mistakes
The most frequent error is entering the capacity in the wrong unit. Entering watts in a field that expects kilowatts, for example 3500 instead of 3.5, gives a result 1,000 times too high. The second is using the rated capacity as the electricity draw without dividing by the efficiency ratio, which gives a figure several times too low. The third is mixing EER and COP, so that a cooling ratio is used for heating or the reverse. Finally, hours per day and days per month must be entered as separate values, not as totals for the month.
Checking the estimate against your bill
Compare one full month of metered use with the estimate for the same hours and days. The two will not match exactly, because the estimate uses rated conditions. If actual use is much higher than estimated, possible causes include blocked filters, low refrigerant or a fault in the unit, the unit running in heating mode when you expected cooling, or other appliances on the same bill. Ask a qualified technician to diagnose the unit before concluding that the equipment is at fault.
Electrical installation
Air conditioners are usually supplied on their own circuit, and the cable and protective device must be sized for the unit's rated electrical input, not its cooling capacity. This calculator does not size circuits. Electrical work should be done by a registered electrician, and the installation should follow AS/NZS 3000, the Wiring Rules, for the 230 V, 50 Hz supply used in New Zealand.
Standards and sources
EN 14825 defines the test and rating methods for air conditioners and heat pumps, which is the basis for comparing their efficiency ratios. AS/NZS 3000 sets the wiring rules for electrical installations in New Zealand. The efficiency values in this calculator are inputs from the user's own data sheet, and the calculator does not assume any particular product.
Frequently asked questions
How much electricity does a 3.5 kW air conditioner use per hour?
A 3.5 kW unit with a cooling EER of 3.6 draws about 0.97 kW of electricity while running in cooling mode, since 3.5 ÷ 3.6 ≈ 0.97. In heating mode with a COP of 4.0, the draw for the same rated output is about 0.875 kW. Multiply the kW figure by the hours run to get kWh, then by the rate per kWh on your power bill to get the running cost. Enter your own figures into the calculator to see the monthly total.
Does heating use less electricity than cooling on the same unit?
Often, yes. The heating COP on many split units is listed higher than the cooling EER, so the same rated output needs less electricity in heating mode. In the worked example, a 3.5 kW unit with an EER of 3.6 uses about 0.97 kW in cooling, while the same output in heating with a COP of 4.0 uses about 0.875 kW. The difference varies by model and by outdoor temperature, and heating efficiency generally falls in very cold weather, so check the data sheet for the figures that apply to your unit.
How many kWh per month does a 3.5 kW air conditioner use?
For a 3.5 kW unit with an EER of 3.6, running 6 hours a day for 30 days, the estimate is 3.5 ÷ 3.6 × 6 × 30 ≈ 175 kWh per month. The same unit with an EER of 3.0 would use 210 kWh over the same period. Use the EER from your unit's data sheet rather than a general figure, and enter your own hours per day and days per month.
Which electricity rate should I enter in the calculator?
Use the price per kWh shown on your own power bill. Rates vary with the retailer, the plan, and whether your plan charges different rates at different times of day. If you run the unit mainly in one period, use the rate that applies then. Check whether the rate includes GST, and enter the rate you will actually pay. The reference value in the calculator is only a starting point and should be replaced.
Is it worth switching the air conditioner off for a short trip out?
It depends on how long you are away and on the weather. For short absences in hot weather, raising the setpoint a little is usually better than switching off, because a room that heats up quickly can need more energy to cool back down than it would have used at a modest setpoint. For absences of several hours, switching off generally saves energy. Timers and eco modes can help if your unit supports them.
When should I get a technician to check the unit's energy use?
Consider a check if your metered use is clearly higher than the estimate for the same hours and days, or if the unit runs but seems less effective at heating or cooling. Possible causes include blocked filters, a refrigerant problem or a fault in the unit. Have any work done by a qualified technician. Regular servicing, as set out in the manufacturer's maintenance schedule, helps keep the unit efficient and extends its working life.
View all Climate & Energy calculators →
By RivoCalc · Reviewed under our editorial methodology · Updated 3 June 2026
Results are estimates based on the rated efficiency of the unit (EER or COP) and the hours and days you enter. Real electricity use varies with the equipment, the outdoor climate, the size and insulation of the room, how the unit is set and how well it is maintained. Check your power bill for actual consumption.