Aluminium Window Cost Calculator: Area and Installation
Estimates the cost of aluminium windows by area, glazing type and profile, with optional installation, for Singapore homes.
Four windows measuring 1.2 m wide by 1.5 m high give 7.2 m² of glazed area in total, and that is the figure the price per square metre is applied to. Add the installation charge per window and the sum is the estimate this calculator produces. The same four windows can cost noticeably more with double glazing and a thermal break than with single glazing in a plain profile, so the glass and frame choices matter as much as the number of units.
Windows shape thermal and acoustic comfort in a home more than most building elements, yet they are one of the items most often underestimated in renovation budgets. Replacing every window in a typical Singapore flat or landed house can account for a large share of an external renovation, and the total rises quickly once the work includes removing old frames, making good the wall openings and fitting new sills. In a climate where air conditioning runs for much of the year, the glass and frame also determine how much cooling load the window adds, which makes the specification a running-cost question as well as a comfort one.
Aluminium windows in Singapore are usually supplied by window fabricators who buy extruded profiles from manufacturers and assemble the units in their workshop. Profiles are sold as named series, and two quotes with the same price per square metre can describe very different products, with different profile thickness, glazing and hardware. The calculator therefore asks for the choices that drive the price most: the glazing type (single, double, or double with low-emissivity coating), whether the profile has a thermal break, and whether installation is included.
Use the result as a planning figure. It assumes that all the windows share the same width, height and specification, and it does not include structural design, wind load checks, scaffolding, or work on a complex facade. Enter your numbers, then take the estimate to two or three written quotes from fabricators with verifiable references on similar jobs, and check that every quote states the same specification.
The result updates automatically.
Count aluminium windows and glazed doors
Bedroom: 1.0–1.4 m (about 3.3–4.6 ft) · Living room: 1.4–2.0 m (about 4.6–6.6 ft)
Bathroom: 0.6–0.9 m (about 2–3 ft) · Bedroom: 1.2–1.5 m (about 3.9–4.9 ft)
Uw ≈ 1.4–2.0 W/(m²·K) · The most common choice · Meets thermal requirements in most cases
The price per square metre is a planning placeholder covering material and fabrication only. It varies with glazing type, profile and finish, and installation is charged per window. Replace it with the figure from your fabricator's quote.
Covers removal of the old window, fitting, sealing and adjusting the sashes.
Installer's labour for each window replaced.
Estimated total cost
6 windows · 10.1 in total
- Material (manufacturing)
- $3,679
- Installation
- $390
- Total (estimate)
- $4,069
- Area per window
- 1.68 m²
- Total area
- 10.1 m²
- Price used
- $365/m²
How it works
Formula
How the calculation works
Aluminium window costs: what sets the price
This calculator estimates the total cost of a set of windows that share the same size and specification. It multiplies the glazed area of all the windows by a price per square metre, then adds an installation charge per window when that option is selected. The result is a planning figure for setting a budget, not a quotation, and it does not replace written prices from fabricators.
How the formula works
The total is calculated as C = N × (L × H) × Pm + N × Pi. N is the number of windows. L and H are the average width and height of each window in metres, so L × H is the area of one window in square metres. Pm is the price per square metre of window, and Pi is the installation charge per window. The first term is the material and fabrication cost, and the second is the labour of fitting.
Because the area is multiplied by the number of windows, a set of six windows of 1.0 m by 1.2 m has 7.2 m² of glazed area in total, and the material term is six times the area of a single window. If you enter averages, keep in mind that the material estimate depends only on total area: a few large windows and many small ones with the same total area give the same material figure, but installation still depends on the number of windows. Changing a width or a height changes the area directly, so check the sizes carefully before entering them.
The edge cases are simple. If the number of windows is zero, the total is zero. If installation is not included, the Pi term is removed and only the material cost remains. A zero or negative width or height has no physical meaning and should not be entered; check the figure against the actual openings instead.
The profile: with or without a thermal break
The profile is the aluminium frame that holds the glass and fixes the window to the wall. A standard profile is a single extruded aluminium section, and aluminium conducts heat very readily. Heat moves through it from the warm side to the cool side, so in an air-conditioned room the frame adds to the cooling load, and the frame edges run colder than the centre of the glass. When humidity is high, that cold edge can show condensation and staining, and over time it can encourage mould in the corners of a room.
A thermal break reduces this by inserting a polyamide barrier between the outer and inner parts of the profile, which interrupts the path of heat conduction. Profiles with a thermal break cost more than plain profiles. The premium varies with the series and the fabricator, so take the difference from written quotes rather than relying on a general percentage. Whether the premium is worth paying depends on comfort and running costs over the life of the window, so compare the difference in the written quotes before deciding.
The glass: single, double and low-e
Single glazing uses one pane, typically 4 mm or 6 mm thick. It has a high thermal transmittance (U-value) and lets a large amount of heat through. It is rarely appropriate for a space that is air-conditioned, although it may suit a store room or a covered utility area.
Double glazing uses two panes separated by a sealed air or argon gap. Compared with single glazing, it lowers the U-value considerably, and the width of the gap, the spacer and the gas used all affect the result. A typical specification is a 4 mm pane, a 16 mm gap and a second 4 mm pane, written as 4/16Ar/4 when the gap is filled with argon. Double glazing is a common minimum specification for new work in an air-conditioned home.
Double glazing with a low-emissivity (low-e) coating adds a thin metallic layer that reduces the transfer of radiant heat. Its U-value is lower again than that of standard double glazing. In a tropical climate the most relevant figure is often the solar heat gain coefficient (SHGC) rather than the U-value alone, because much of the unwanted heat enters through direct sunlight on the glass. A coating with a low solar factor can reduce the cooling load on west- and east-facing rooms, which is usually a better reason to choose low-e than the U-value figure.
The glazing U-value refers to the glazing unit only. The overall window value, Uw, also takes in the frame, so good glass in a poor frame gives a window that performs less well than the glass figure suggests. The calculator does not compute Uw, so ask the fabricator for it directly.
Installation and site conditions
The installation charge is applied per window, not per square metre, so the number of windows affects the total as much as their size. Installation costs rise for large or heavy units, for openings that are hard to reach, when access requires scaffolding or a lift, and when old frames must be removed and the wall opening made good. A window in an older building with an irregular or poorly finished opening may need more preparation than the number of units suggests. A 4-room HDB flat with four windows of the same size, for example, can be quoted quite differently from a landed house where each opening is different.
Before any work starts, check whether external changes need approval. In a condominium, works to the external facade often need the approval of the management corporation. In an HDB flat, check the rules that apply to changes to external windows before ordering. Building works are governed by the Building Control Act and the requirements of the Building and Construction Authority, and a qualified professional should confirm that the proposed windows and their fixing comply with what applies to the building.
For new openings or any change to the structure, the window design must consider wind loads. The design wind pressure is derived from SS EN 1991-1-4 (wind actions), as applied in Singapore through its National Annex, and the window must resist that pressure. Wind resistance of windows is tested under EN 12210.
Standards and performance tests
Window performance is assessed through laboratory testing, and the manufacturer's declaration of performance shows which results apply to a given product. The relevant European product standard for windows and external pedestrian doors is EN 14351-1. Three performance classes are usually quoted:
- Resistance to wind load, tested under EN 12210.
- Air permeability, classified under EN 12207.
- Watertightness, classified under EN 12208.
Ask the fabricator for the classes achieved by the proposed product, not just the series name. Local authorities may impose additional requirements, so these European standards are a reference point rather than the full answer for a Singapore project.
Common mistakes
Measuring the opening incorrectly. The dimension to give the fabricator is the size of the rough opening, wall to wall, with a clearance of about 10 to 15 mm per side for fixing and sealant. Quoting the size of an old window is risky, because older frames may have uneven gaps or poor fixing, and the new unit has to fit the actual opening.
Comparing quotes without a specification. Two quotes with the same price per square metre can describe very different products. Ask for the profile series name, the glazing make-up (for example 6 mm, 12 mm argon gap, 6 mm low-e), the air permeability and watertightness classes, and whether hardware, the external sill, perimeter sealant and gaskets are included.
Assuming accessories are included. Locking hardware, hinges, the external sill, perimeter sealant and gaskets are part of many quotes but not all of them. Confirm the full list before signing.
Forgetting the finish. Colours and surface finishes can change the price per square metre. The calculator takes a single figure, so make sure the figure you enter matches the finish in the quote.
When to use this calculator and when not to
Use it to set a budget, to compare glazing options, or to see how the number of windows and their size change the total. For example, the owner of a condominium unit in Bukit Timah might compare double glazing with a thermal break against low-e glazing with a thermal break for a west-facing living room. Entering the same window sizes for both runs shows the material difference, while the installation figure stays the same because the number of windows does not change.
Do not use the result as a final quotation, for structural design, for curtain walls, for sliding systems or for unusually large openings, and not for any work that needs an engineer's sign-off. For those, a qualified professional should provide the design and a written price.
The result is only as good as the inputs. Averages hide differences between windows, and a single price per square metre cannot capture a mix of finishes or glazing within the same job. If the job includes different specifications, run the calculator separately for each group of windows and add the results together.
Frequently asked questions
What determines the cost of aluminium windows in Singapore?
The main factors are the glazing type (single, double or double with low-emissivity coating), the profile (with or without a thermal break), the size of each window, the finish, and whether installation is included. Glazing and profile choices affect the price per square metre, while installation is charged per window and rises with difficult access, large units or removal of old frames. Enter the number of windows, their average width and height, and the price per square metre from your quote to see a planning figure.
Is a thermal break worth paying more for?
In an air-conditioned home, usually yes. A plain aluminium profile conducts heat readily, so the frame adds to the cooling load, and its edges can run cold enough to show condensation and staining when humidity is high. A thermal break interrupts that path. Compare the price difference with the fabricator's quote for the same glazing, and weigh it against the effect on comfort and running costs over the life of the window. The benefit is clearest on windows that receive direct sun or sit in rooms that are air-conditioned for long hours.
What is the difference between double glazing and low-e glass?
Double glazing uses two panes with a sealed gap, which lowers the U-value considerably compared with single glazing, and the width of the gap and the gas used both affect the result. Low-e glass adds a thin coating that lowers the U-value further. In a tropical climate the solar heat gain coefficient (SHGC) matters as much as the U-value, because much of the unwanted heat arrives through direct sunlight. Ask the fabricator for the SHGC of the glazing as well as its U-value.
What should I ask a fabricator to compare quotes properly?
Ask for the profile series name, the glazing make-up (for example 6 mm, 12 mm argon gap, 6 mm low-e), the air permeability class under EN 12207, the watertightness class under EN 12208, and the wind resistance class under EN 12210. Also confirm whether hardware, the external sill, perimeter sealant, gaskets, removal of the old frame and installation are included. Quotes without these details are not comparable, because a lower price can mean thinner profiles or glazing with lower performance.
Do I need approval before replacing windows in Singapore?
It depends on the type of property and the work. In a condominium, external changes to the facade often need approval from the management corporation. In an HDB flat, check the rules for changes to external windows before ordering. Structural work, new openings or changes that affect the building envelope may need submissions to the Building and Construction Authority under the Building Control Act. A qualified professional can confirm what applies to your building before you sign a contract.
Is this calculator enough to order windows?
No. The calculator gives a planning estimate based on averages, a single price per square metre and a single installation charge per window. It cannot account for site access, the condition of the existing opening, the finish, or the structural and wind load requirements of the building. Use the result to set a budget and to decide which options to compare, then ask for written quotes from at least two or three fabricators with references on similar jobs.
Related calculators
View all Climate & Energy calculators →
By RivoCalc · Reviewed under our editorial methodology · Updated 3 June 2026
This calculator gives an estimate for planning purposes only. Actual costs depend on the profile series, glazing specification, site access, finish, the condition of the existing opening and the fabricator's quote, and real results will vary. Check the figure against written quotes before making any decision.